        2. Lanmec has Jiangsu torque measurement and control technology R & D center, torque sensor division, dynamometer division and tension division

          Service hotline:

          400-111-3688
          Location:Home > Products
           CW series eddy current brake
           Hits:14601 AddTime:2021/9/10 10:00:56

          Eddy current brake, as a kind of load, mainly used to measure the dynamic mechanical properties of test equipment, it and other control measuring instrument can be eddy current dynamometer.Can be used for internal combustion engine, motor, gas turbine, automobile and machinery components performance test, compared with other dynamometer device, the CW series dynamometer device has higher reliability, stability, and practical.
          Main features:
          1. Simple structure, stable operation, low price, convenient in operation and maintenance.
          2. Use water cooling, low noise, small vibration.
          3. Enter the wide speed range.
          4. All previous control power is small, the single-phase dc power supply.
          5. With measurement and control system, which can realize automation control.
          6. Used as a brake, a braking force is large, the advantages of good and stable performance.
          Working principle:
          1. The base to structure of the CW series eddy current brake (see below)

          The CW type eddy current brake (with groove wheel), by the rotor stator (including around the armature, excitation coil, end cover, bearing cover), frame composition.
          Eddy current ring around the armature body (with) have the same cooling waterway, set in the excitation coil is installed before the two armature body, after the cooling water from inlet to the armature into vortex ring cooling water tank, lower body but buckle from the upper half of the armature body flow in and out of the gate, through the outlet flow out.
          2. The working principle of the CW series eddy current brake
          When the rotor with coaxial excitation coil assembly to pass a dc TV, its produce magnetic menstruation armature, eddy current ring, air gap and the rotor to form closed magnetic circuit.Due to the rotor outer surface is made into uniform distribution of teeth and slots, so in the air gap and vortex ring surface density can be found in the magnetic field.Therefore, when the rotor is dragging rotates, the eddy current ring as a point on the surface of the magnetic field to produce alternating changes, the induction, the magnetic field which is formed by the "vortexing" and interact with the original air-gap magnetic field, creates a braking torque on the rotor.Engine output power is converted into vortex ring "vortexing" to produce the equivalent of heat, the heat by the eddy current ring into the continuous cooling water in cooling water tank.
          The main technical parameters:

          Model
          input speed(r/min)
          Rated torque(N.m)
          Rated Power(kW)
          Excitation Voltage(V)
          Ecitation Current(A)
          Cooling water(L/min)

          Weight

          (Kg)

          Remark
          CW5B
          300-3600
          5
          0.75
          <90DC
          <5
          1
          36

          Speed for constant torque under 1500 r/min, More than 1500 r/min for constant power.

          CW10B
          10
          1.5
          1
          40
          CW20B
          20
          3
          2
          52
          CW50B
          50
          8
          5
          83
          CW100B
          100
          15
          8
          120
          CW200B
          200-3200
          200
          30
          15
          210
          CW300B
          300
          45
          25
          300
          CW650B
          650
          100
          <180DC
          <10
          55
          730
          CW1000B
          1000
          150
          80
          1200
          CW2000B
          2000
          315
          160
          2470
          CW3000B
          3000
          470
          <20
          240
          3522
          CW6500B
          6500
          1000
          <40
          550
          4600
          CW10000B
          10000
          1570
          <60
          800
          5800
          CW14000B
          14000
          2200
          <90
          1100
          8200

          4.3 Characteristic curve


          Note: P0: Maximum cooling power

          n1: Rated minimum speed

          n2: Rated maximum speed

          Figure 2

          5. Outlinge and installing dimension (As following table)


            Figure 3

          Type

          安裝尺寸 (mm)

          Installing dimension(mm)

          外形尺寸不大于 (mm)

          Max of outlinge and dimension

          A

          B

          C

          D

          E

          F

          G

          H

          K

          AB

          HD

          L

          CW 5B

          160

          160

          8

          19

          40

          6

          15.5

          100

          12

          210

          245

          256

          CW 10B

          190

          170

          21

          24

          50

          8

          20

          112

          12

          230

          256

          310

          CW 20B

          216

          140

          30

          28

          60

          8

          24

          132

          12

          272

          310

          324

          CW 50B

          279

          210

          30

          38

          80

          10

          33

          160

          19

          340

          365

          410

          CW 100B

          279

          267

          26

          42

          110

          12

          37

          180

          19

          350

          410

          450

          CW 200B

          356

          267

          30

          55

          110

          16

          49

          225

          19

          455

          510

          480

          CW 300B

          406

          356

          45

          65

          140

          18

          58

          250

          28

          506

          570

          595

          CW 650B

          457

          356

          40

          60

          105

          18

          53

          280

          28

          570

          650

          560

          CW 1000B

          506

          406

          40

          65

          105

          18

          58

          315

          28

          620

          720

          600

          CW 2000B

          610

          457

          40

          70

          105

          20

          62.5

          355

          35

          775

          770

          655


          Note: The outlinge and installing dimension of standard product are shown as above table. Please in kind prevail.

          6. Usage, transportation and storage of electric eddy current brake

          6.1 The environment temperature of electric eddy current brake is 0 — +40, the relative humidity is not more than 85%. Install the device below 1000 meters above sea level.

          6.2 Electric eddy current brake should be installed on a solid foundation without any shock vibration and the surroundings shall be free of acid, alkali, salt and other harmful substances.

          6.3 Transportation and storage temperature: - 30  ~ + 50  (hydrops in the cooling system shall be emptied); Transportation can be carried out in the case of packing. The speed shall keep less than 30+5 km/h on tertiary highway. Both railway and waterway are permitted.

          6.4 Because the power generated by the tested machine is absorbed by electric eddy current brake, CW series electric eddy current brake shall be equipped with water in case of operation. Or the electric eddy current brake would be burnt out.

          With the exception of a few heat dispersed through the shell, most heat generated by the power absorption is concentrated on the eddy current component. Therefore, as shown in Figure 1, there are several cooling water flow channels on the back of vortex ring. The external cooling water passes the flow channel and makes heat exchange with magnetic ring. The heated water runs away through pipes.

          Cooling water is an important guarantee to ensure the normal operation of electric eddy current brake. The pipe with special dimension shall be installed at the inlet and outlet of eddy current brake. To inspect the leakage of water supply system and the prescribed value of water flow by means of water testing.

          The cooling tap water and water in circulating pool can be used as the cooling water. When using circulating pool, the heat dissipation of cooling water shall be taken into consideration with the inlet temperature of≤25. The cooling water shall be clean tap water without salt, alkali and other corrosive substances, which can prevent the rapid formation of incrustation. Users can identify and judge the local water quality and take measures to prevent incrustation formation, especially in hard water areas. Or the channel of eddy current brake would be blocked quickly. And also, users can add anti-rust agent and anti-fouling additives to prolong the service life of eddy current brake.